Summary of Contents

Page 1 - ATTO FastStream SC 5300

ATTO Technology, Inc. ATTO FastStream SC 5300Installation and Operation ManualFibre Channel to SCSI Storage Appliance© 2006 ATTO Technology, Inc. Al

Page 2

3ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 1.1 Physical attributesThe ATTO FastStream SC 5300 is a Fibre Channel to S

Page 3

4InstallationLED indicatorsThe LED indicators can be viewed from the connector side and the front side of the FastStream SC 5300. (See Exhibit 1.1-1)L

Page 4 - Contents

5ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 2.0 InstallationIf you have not already completed the instructions on the

Page 5

6Internet Explorer setup1 Open your browser2Select Internet Options.3 In the Internet Options screen, select the Security tab.4 Click on the Trusted S

Page 6 - Contact ATTO Technology, Inc

7ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 2.1 Configure RAIDThe ATTO FastStream SC 5300 allows configuration of stor

Page 7

8Select an applicationWhen you select an application, the FastStream SC 5300 finds all available drives and creates the appropriate setup using those

Page 8

9ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual2 Click on Next. NoteDepending on your choice and your current system, the a

Page 10 - 1.1 Physical attributes

11ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 2.2 Partition RAID groupsA RAID group may have several Terabytes of total

Page 11 - LED indicators

123 Click on the RAID Groups arrow 4 Click on the Modify RAID Group Partitioning button5 Click Next6 Select the RAID Group Name from the drop down men

Page 13 - Begin initial configuration

13ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 2.3 Use Hot SparesIf a member of a virtual device becomes degraded or fau

Page 15 - Select an application

15ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 2.4 Optional changes to system setupDefault values are appropriate for mo

Page 16 - Custom initial setup

162 In the left-hand menu, click on the Advanced menu item.3The Advanced CLI Configuration page appears. Wait for the Ready prompt, then type in the C

Page 17

17ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 3.0 Monitor storage, configurationsYou may determine the performance of d

Page 18 - 2.2 Partition RAID groups

18Display page (refer to Configuration Display page below). • RAID Group StatusRAID Group names, RAID status, available Hot Spares and number of faul

Page 19

19ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual3The Manage Menu page appears. Click on the FastStream arrow. 4 Click the S

Page 20 - 2.3 Use Hot Spares

20If the verify operation detects an error, the FastStream tries to re-initialize the drive, erasing information stored on the drive. Be sure to back

Page 21

21ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 4.0 Modify storageUse the ExpressNAV interface to replace a failed drive,

Page 22 - Advanced CLI page

22RAID group processesCAUTIONCAUTIONClicking on Commit during RAID configuration causes all previous storage data on the drive to be erased. Ensure al

Page 24

23ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual• RAID Level 0 to RAID Level 10• RAID Level 1 to RAID 10 • N-way mirrori

Page 25 - Configuration Display page

24FastStream process: add or remove Hot SparesFor an explanation of Hot Spares, refer to Use Hot Spares on page 13.1 Follow the instructions in Prelim

Page 26 - Identify drive issues

25ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 5.0 Update firmware, configurationsYou can update the ATTO FastStream SC

Page 27 - CAUTIONCAUTION

26Initialize storageInitializing unattached storage may be used to remove stale RAID configuration data from a drive that is known to be in good healt

Page 28 - 4.0 Modify storage

27ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 6.0 Interface optionsThe best way to manage, monitor and configure the Fa

Page 29 - RAID group processes

28Use TelnetUp to three Telnet sessions can be conducted simultaneously. A serial port session can use the CLI while Telnet sessions are open. Whichev

Page 30

iATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualAppendix A CablingAdditional information to physically connect ports to de

Page 31

iiAppendix2 Check the type of cable, cable length limit and number of devices recommended for the port. See Exhibit A-1. Keep cable lengths as short

Page 32 - Update firmware

iiiATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualAppendix B Designing RAID groupsThe ATTO FastStream SC 5300 provides ins

Page 33 - Initialize storage

ivAppendixRAID Level 0 provides no data protection. If one If one drive fails, all data within that stripe set is lost.The ATTO FastStream SC 5300 sup

Page 34 - 6.0 Interface options

Contents 1.0 ATTO FastStream SC 5300 offers data protection ...1FastStream featuresRAID protection featuresAudio/video features 1

Page 35 - Use Telnet

vATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualAppendix C CLI provides an ASCII-based interfaceThe command line interface

Page 36 - Appendix A Cabling

viAppendixCLI error messagesThe following error messages may be returned by the Command line InterfaceERROR. Invalid Command. Type 'Help' fo

Page 37 - Fibre Channel connections

viiATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualDriveTestList drivetestlist allDriveTestStatus get driveteststatusDumpConf

Page 38

viiiAppendixPartitionSplit partitionsplit alpha1 22 2Password Password set password Performance get performance 2Ping ping mp1 192.42.155.155RAIDComma

Page 39 - Appendix

ixATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualCLI command explanationsCommand Line Interface commands are listed alphabet

Page 40

xAppendixBlockDevIdentifyCauses the I/O LED of the drive to illuminate for one minute if it is accessible through the FC port.CAUTIONCAUTIONThe BlockD

Page 41 - CLI summary

xiATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualDisplayEventLogFilterFilters the display of data for specified subsystems a

Page 42

xiiAppendixEmailPasswordConfigures the password used to authenticate the login to the SMTP E-mail server. The password must not be more than 64 charac

Page 43

xiiiATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualFCDataRateSpecifies the rate the FastStream uses, 1 Gigabit/sec., 2 Gigab

Page 44 - CLI command explanations

xivAppendixHSDisplay Lists all devices in the Hot Spare pool. HSDisplay HSRemove Removes a Block Device from the Hot Spare pool HSRemove [BlockDevID]

Page 45

3.0 Monitor storage, configurations ...17Health and Status Monitor pageConfiguration Display pagePho

Page 46

xvATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualPartitionSets the specified partition to the specified capacity in Gigabyte

Page 47

xviAppendixRAIDRebuildPrioritySets or displays the RAID rebuild priority. A RAID rebuild priority set to high gives higher priority to RAID rebuilds a

Page 48 - fp1=3; fp2=4

xviiATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualRGHaltConversion Stops the conversion on the specified existing RAID grou

Page 49

xviiiAppendixRGWaitTimeout Specifies the maximum time in seconds that the system waits to discover previously-configured RAID groups attached to the d

Page 50

xixATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualSCSIPortList Lists the status of all available SCSI ports.SCSIPortListSCSI

Page 51

xxAppendixTailEventLog Displays new events to the terminal. Type q and press Enter to exit tail mode.TailEventLogTemperature Displays the current inte

Page 52

xxiATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualAppendix D Standards and compliancesThe equipment described in this manu

Page 53

xxiiAppendixEuropean StandardsDeclaration of ConformityThis following statement applies to the ATTO FastStream SC 5300. This device has been tested in

Page 54

xxiiiATTO Technology Inc. FastStream SC 5300 Installation and Operation ManualAppendix E Warranty, contact informationManufacturer limited warrantyM

Page 55

xxivAppendix

Page 56 - Canadian Standards

Appendix C CLI provides an ASCII-based interface ...vCLI error messagesCLI summaryCLI command explanationsAppendix D Standard

Page 58

1ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual 1.0 ATTO FastStream SC 5300 offers data protectionThe ATTO FastStream SC 5

Page 59

2IntroductionSCSI Tape LibraryATTO iPBridge 27004-Gb FC SwitchPossible storage configurationsEthernetFibre ChannelSCSIembedded ATTO iPBridge1500/1550